Martindale HPAT500/2 PAT Tester

Martindale Official Distributor
  • Straightforward operation thanks to pre-set test sequences
  • Carries out testing on Class I, Class II and IEC extension leads
  • Provides PASS/FAIL indication alongside numeric results

Free gift

Includes: 110V appliance adaptor, 500 PASS labels, 200 FAIL labels, 250 Passwrap labels, IEC cloverleaf adaptor, and PAT register book.

Optional Extras

£318.00+VAT
In stock
+

Free gift with this product

Martindale Accessory Bundle
Martindale PAT Accessory Kit
Worth £85.00

Includes: 110V appliance adaptor, 500 PASS labels, 200 FAIL labels, 250 Passwrap labels, IEC cloverleaf adaptor, and PAT register book.

Product videos

Description

The Martindale HPAT500/2 PAT Tester is an ideal instrument for low-volume PAT testing in offices and residential environments. It is a great choice for beginners to PAT testing thanks to its simple operation and portable, lightweight design.

The Martindale HPAT500/2 can perform earth bond testing, insulation testing, polarity and fuse testing which are organised in pre-set test sequences. It is suitable for Class I and Class II appliances and IEC leads and provides both a PASS/FAIL indication alongside test results. The 200mA earth bond test is IT-safe.

The internal rechargeable batteries power the Martindale HPAT500/2 and supplied accessories include a test lead with crocodile clip, a 230V extension lead, a mains lead and a carry case.

Key Features

  • Simple three-button operation
  • Suitable for domestic and IT requirements
  • Class I and Class II appliances plus power leads
  • Provides PASS/FAIL indication with numeric value

Specification

EARTH CONTINUITY

  • Test voltage: 4V DC (into open circuit) Test current: 200mA DC (into short circuit)
  • Range: 0 – 19.99Ω
  • Resolution: 0.01Ω
  • Accuracy: ± (5% of reading + 2 digits) Fixed pass limits:
  • Lead: ≤ 0.10 Ω = PASS; ≤ 0.20 Ω = NOTE x.xx PASS
  • Class I: ≤ 0.10 Ω = PASS; ≤ 0.20 Ω = NOTE x.xx PASS

If NOTE x.xx Ω PASS is displayed, end user of HPAT should take note of the Earth Continuity resistance value and reach a pass/fail decision for the appliance.

INSULATION

  • User Selectable Voltage: >500V DC at 1mA (<625V DC into open circuit); >250V DC at 1mA (<312.5V DC into open circuit)
  • Test current: 1.5mA (into short circuit)
  • Ranges: 2.00MΩ, 20.0MΩ, 200MΩ
  • Resolution: 0.01MΩ
  • Accuracy: <100MΩ ± (5% reading + 2 digits)
  • >100MΩ ± (10% reading + 2 digits) Fixed pass level:
  • Lead: ≥ 1.0 MΩ Class I: ≥ 1.0 MΩ Class II: ≥ 2.0 MΩ

FUSE CHECK

  • Test voltage: 4V DC (into open circuit)
  • Test current: 200mA DC (into short circuit)
  • Pass level: >2mA

GENERAL

  • Overload protection: 300V AC/DC
  • Protection class: IP20
  • Safety: Complies to BS EN 61010-1
  • Temperature Range: -10 to 40°C, non-condensing Batteries: 6 x 1.2V AA NiMH rechargeable batteries 1800mAh, or greater
  • Caution – use only the battery type specified
  • Battery Life: Fully charged, minimum 600 complete tests. The HPAT500 will operate fully from the battery charger in the event of discharged batteries. Do not remove batteries.
  • Auto Power Down: After 10 minutes of inactivity, or when battery low
  • Battery Charger: Input: 230V 50Hz; Output: 12VDC at 300mA, 5.5 jack x 2.5 bore centre positive
  • Dimensions: 90 x 210 x 54mm
  • Weight: Approx 700g (including batteries & leads)

Supplied Accessories

The Martindale HPAT500/2 comes with:

  • Test Lead with crocodile clip
  • 230V Extension Lead Adaptor
  • Mains Lead
  • Instruction Manual
  • 12 Month Warranty
  • 6 x AA Rechargeable Batteries
  • Carry Case